Annex 4a - RAI Gas Storage Procedure
Why this procedure exists
This procedure describes how RAI Amsterdam manages the licensed gas storage facilities on its premises.
What we agree on regarding gas storage
Under PGS 15, each process location, for example at a forklift truck or gas-fired fryer, may have no more than one connected gas cylinder and one spare gas cylinder present. Storage of a stock of gas cylinders is only permitted in RAI Amsterdam’s designated gas storage facilities. DSV has been appointed as the manager of these gas storage facilities.
RAI Amsterdam has two licensed gas storage facilities:
- P-5a:
- 1 DSV storage facility; and
- 1 storage facility for gas cylinders found by RAI Amsterdam Health & Safety.
- P-10 (opposite door 7.15):
- 2 DSV storage facilities;
- 1 Trompetty storage facility;
- 1 Coverfloor storage facility;
- 1 CSU / Bnext storage facility;
- 1 A-Booth storage facility;
- 1 Real Estate / Kitchen RAI Amsterdam storage facility;
- 1 storage facility for gas cylinders found by RAI Amsterdam Health & Safety; and
- 1 storage facility for third parties during events.
All individual gas storage facilities are fitted with a combination lock.
The code is known to: i) the relevant user, ii) DSV, iii) the Real Estate department and iv) the Health & Safety department. The code may not be changed without the permission of RAI Amsterdam Real Estate and Health & Safety. Requests may be submitted to Health & Safety (safety@rai.nl).
The full storage location at P-10 is secured by a sliding gate. This access code is also provided to all users. The sliding door closes automatically after use. Gas cylinders, whether full or empty, must always be stored in a designated cage. A gas cylinder located behind the sliding door but not placed in a cage is deemed to be an unattended, loose gas cylinder and is treated as such. The closed sliding door is not considered to secure the gas storage facility.
The gas cylinders supplied by DSV are fitted with an Easyclip connection.
If a different connection is required, the user must provide a suitable adapter.
What RAI Amsterdam suppliers do
As standard, DSV supplies four full gas cylinders to the user’s storage facility. During the day, DSV carries out checks and exchanges empty gas cylinders for full ones where necessary. If additional gas cylinders are required during the weekend, DSV must be notified no later than two working days in advance. The contact details for the DSV branch at RAI Amsterdam are provided below.
If RAI Amsterdam identifies a breach when working with gas cylinders, this will be discussed with the user and the relevant contract owner within RAI Amsterdam.
What temporary users of gas storage facility P-10 do
Under PGS 15, each process location, for example at a forklift truck or gas-fired fryer, may have no more than one connected gas cylinder and one spare gas cylinder present. If this condition is met, the user may arrange for gas cylinders to be delivered for their own use. To prevent unattended gas cylinders in and around RAI Amsterdam, these must be taken directly to the relevant user locations after delivery.
If the above conditions cannot be met, the user must contact DSV to hire gas cylinders.
This must be done no later than four (4) weeks before use. The contact details for the DSV branch at RAI Amsterdam are provided below.
Additional arrangements regarding the use of hired gas cylinders may be made directly with DSV. DSV can provide bespoke solutions and applies market-based rates for its services.
If RAI Amsterdam identifies a breach when working with gas cylinders, this will be discussed with the user and the event owner within RAI Amsterdam.
Who is responsible for what
- RAI Amsterdam supplier / temporary user:
- Full and empty gas cylinders must be stored separately in the cage; and
- If gas cylinders are to be stacked, this must be done correctly.
- DSV:
- Delivery and collection of gas cylinders;
- Full and empty gas cylinders must be stored separately in the cage; and
- If gas cylinders are to be stacked, this must be done correctly.
- RAI Amsterdam Real Estate (technical management):
- Accuracy of signage in accordance with PGS 15;
- Availability of fire extinguishing equipment; and
- General condition of the storage location and the associated maintenance.
- RAI Amsterdam Health & Safety (operational control):
- Checking the correct use of the various storage facilities (order and cleanliness);
- Checking the presence of signage and fire extinguishing equipment;
- Checking the general condition of the storage location; and
- Processing and recording “Found Gas Cylinders”.
How to contact us
| Contact | Telephone number |
| RAI emergency number | +31 (0)20 549 12 34 |
| RAI Health & Safety (operational control) | +31 (0)20 549 30 22 |
| RAI Real Estate (technical management) | +31 (0)20 549 14 60 |
| DSV (operational management) | During office hours: +31 (0)20 225 39 73 Outside office hours: +31 (0)6 257 433 97 E-mail: fairs.amsterdam@dsv.com |
This Annex 4a 'RAI Gas Storage Procedure'
is attached to the Accommodation Regulations,
was prepared by Safety & Security and
was last updated on 1 August 2026.